- Kiil dialyzer 基尔平板型透析器, 平板型透析器
- The dialyzer reuse may ameliorate membrane biocompatibility. HE膜和PS膜生物相容性优于CA膜 ,透析器复用可改善透析膜的生物相容性
- Dialyzer clotting occurred less than in control group. 监测血尿素氮、肌酐等。
- Water processing system is a set of device supplying qualified water for a dialyzer s normal operation. 水处理系统是为保障血液透析机正常运行而提供符合透析用水的装置。
- The dialyzer is a circulating equipments outside the body for curing acute and chronic kidney function. 血液透析机是用于治疗急、慢性肾功能衰竭的主要体外循环设备。
- All of these changes are associated with the dialyzer membrane"s biocompatibility. 而这些变化与使用的透析膜的生物不相容性有关。
- And the paper advances that medical engineers should pay more attention to the routine maintenance of a dialyzer. 提出医疗器械维修人员应重视平时的维护工作。
- Objective To observe the effect of peracepic acid and formaldehyde used to sterilize dialyzer. 目的:对比观察过氧乙酸与甲醛2种消毒剂在透析器复用中的效果。方法:透析器复用采用0。
- Abstract Water processing system is a set of device supplying qualified water for a dialyzer's normal operation. 反渗透膜水处理技术是一种先进和节能的膜分离技术。
- CRRT can significantly improve prognosis of patients with ARF and dialyzer reuse is worth of further application. 患者年龄越大、既往健康状况越差、衰竭脏器个数越多重症ARF的预后越差,CRRT可明显改善肾性ARF的预后,日间CRRT的开展,滤器的重复使用对该技术的临床推广有重要价值。
- This paper introduces the classification of the faults of BELLCO dialyzer and the methods of eliminating the faults. 本文叙述了意大利产贝尔克血透仪的故障类型及维修方法。
- The whole blood purifying equipment room includes blood dialyzer, a whole set of water treatment and relevant auxiliary equipment. 整个血液净化中心机房设备包括血液透析机、整套完整的水处理及相关辅助设备。
- We regenerate the dialyzer with eclectrolyzed oxidizing water.It can reduce the degeneration of the dialyzer function exceeding. 我们把氧化电解水作血液透析器的复用剂,能最大限度地减少透析器功能的退化。
- Conclusion The technical improvement can not only ensure the water quality, but also make good use of the dialyzer reuse machine and dialysis machines. 结论:该技术改进在保证供水质量的同时,能最大限度地发挥现有设备的效能。
- Fresenius F60 polysulfone dialyzer was used for HFHD group, and Fresenius F6HPS polysulfone dialyzer was used for LFHD group. HFHD组使用聚砜膜F60高通量透析器,LFHD组使用聚砜膜低通量F6HPS透析器,连续观察1年。
- KoA for urea varied with dialyzer model,but the effect of Qb,Qd. Urea KoA did not change significantly when Qb increased from 300 to 500 ml/min at Qd of 500,800 and 1000 ml/ min. 透析液流量(Qd)保持恒定时(分别为500,800,1000 ml/min),尿素KoA在血流量从300增加到400,500ml/min时,KoA并不增加;
- This paper introduces the importance of the routine maintenance for long stable working of a dialyzer by ana-lyzing the reasons and the treatments of three common troubles. 本文以三例常见故障的原因和处理方法说明了平时的维护工作对透析机能长期稳定安全地工作的重要性。
- One of the water needle, metronidazole and dialyzer production ranks first, metronidazole is also exported to Southeast Asia and Europe more than 10 countries and regions. 其中水针、甲硝唑和透析器产量居全国首位,甲硝唑还远销东南亚、欧洲等十多个国家和地区。
- Methods A small water tank was set in the RO water circuit to collect the left RO water to be used by the dialyzer reuse machine and other more dialysis machines. 方法:在原有反渗水回路上增加小型水箱缓存多余反渗水,供更多血透机及透析器复用机使用。
- This article introduces the working principle and structure of air bubble detector in NIPRO dialyzer and analyzes the advantages and disadvantages of two common types of detectors. 本文详细的介绍了NIPRO血液透析机气泡检测器的工作原理和具体结构以及常见类型优缺点。